  • Automatic switching on anf off the lighting
  • Setting the threshold for illumination (button training)
  • The possibility of remote settings via remote button
  • Built-in timer load off after a time delay from 0,5 to 7h -10 positions
  • A wide range of actuation at level of illumination  (0,1-500lux)
  • External photo sensor with protective case for wall mounting
  • Customizable delay of actuation the output relay from 5s to 10min -10 positions
  • Width of case is 18mm
 
PURPOSE OF THE RELAY
 Photorelay FR-M02 is designed to automatically turn on and off street lighting, store windows, commercial halls, advertising, parking lots, etc. depending on the set threshold illumination level. Control illumination level is carried out external photo sensor FD-3-1, supplied separately from the photorelay.
 The relay has a mode of "smart off". In this mode, the user by himself can set the time of the included lighting or advertising after dusk in the range from 30 minutes to 7 hours. In the evening or night time the relay turns on lighting or advertising and after a specified time turns off. The relay can significantly save on electricity consumption.
 The relay can be used to control beacons. When the remote control channel is (radio channel, etc.) can be carried out simultaneously enable remote adjustment of the few beacons. When a channel control commands is filed, the relay "remembers" the level of illumination at this moment. In the future, all the inclusions beacons will occur precisely at this illumination.
 The controll of system automatic irrigation. The relay turns on irrigation and after the set time turns it off without human involvement (example, at the cottage in the absence of man).
 By means of the relay can be controlled a street, stair lighting, turn on heating greenhouses, light advertising, block the electric locks at night, etc. Using the mode "smart off", you can extend the "light day" on poultry farms, greenhouses, etc.
 
DESIGN OF THE RELAY
 Relay is produced in a plastic case with a unified front connection wires power and switched circuits. Mounting is carried out on a DIN rail  width 35mm (GOST R IEC 60715-2003) or on a smooth surface. To set on a smooth surface, spring locks must be changed in recent holes, fixing a spring lock, which are located on the back side of the case. Terminal design provides robust clamp wires up to 2,5mm2. On the front panel there are: rotary switch of actuation time of relay "tdelay", rotary switch of time built-in timer "toff", button "training" for detting photo relay on the necessary illuminance, green/red indicator of powering voltage "U"/"ALARM PHOTO SENSOR", yellow indicator of actuation built-in executive relay.
 
 WARNING:  It is forbidden to carry out any work with photo relay, being under voltage.
 
Preparation for use and operation photo relay:
1. Connect the photo sensor and relay according to the circuit connection. Photo sensor is connected to terminals "T1", "T2". Supply voltage is connected to terminals "A1" and "A2".
 
 WARNING: Relay in the executive to AC current power supply must be connected in compliance with the conditions - wire is under voltage (phase) must be connected to the terminal "A1" (L), and zero - to terminal "A2" (N). Execution of the constant current power supply, the positive pole is always connected to the terminal "A1".
 
2. Set the regulator "tdelay" in the position 5s, and time regulator of built-in timer "toff " in position "∞".
3. Select time of the day, when must be enabled switching the light source. Apply a voltage supply to the relay, and the green LED "U" should light up. Enabling red LED "ALARM PHOTO SENSOR" - points to short circuit between terminals "T1" and "T2". Enabling the relay and alternating flashing red and green LED points that photo sensor is not connected.
4. Press and hold button "training" before enabling a red LED. Let go off button, after 5s relay will remember the light level and turn on the relay, and contacts 11-14 will be closed.
 
 WARNING: When delivered, photo relay is set to the level of illumination - 0,2lux
 
 A customizable time delay of enabling the relay by switch "tdelay " eliminates the effect of short-term fluctuiations of lighting. At counting of this time a green LED "U" flashes with a period 0,5s. Adjustable time delay off by switch "toff" allows to save electricity. At counting this time a green LED "U" flashes with period 2s. In position "∞" a time counting does not occur. Setting the relay can be carried out remotely. Remote mounting is connected parallel to photo sensor to terminals "Т1" and "Т2". Maximum line length is 30 meters. Sensor is supplied depending of the configuration definited by the order code (see contens of delivery).
 
 Sensor FD-3-1: The spectral peak at a wavelength - 590nm, the resistance (illumination 10lux) - 50...140kOm, dark resistance - 20MOm, the response time - 20ms, recovery time - 30ms, range of operating temperature - (-30…+800C), degree's protection - IP65.  
 
SPECIFICATION OF THE PHOTO RELAY FR-M02
A parameter
Unit
FR-M02 DC24V
FR-M02 AC230V
Rated supply voltage
V
DC24 ± 10%
АС230 ± 10%
Power consumption, max
VA
2
The light level - customizable via training method
lux
0,1-500
Duration of the delay on enabling
 
5s, 10s, 15s, 20s, 30s, 40s, 1min, 3min, 5min, 10min
Duration of the delay off the built-in timer
h
∞, 0,5, 1, 1,5, 2, 2,5, 3, 5, 7
Maximum switching voltage 
V
400 (AC1/5A)
Maximum switching current: АС250V 50Hz (АС1)/DC30V (DC1)
A
16
Maximum switching power: АС250V 50Hz (АС1)/DC30V (DC1)
VA/W
4000/480
The maximum voltage between the power supply circuits and relay contacts
V
АС2000 (50Hz - 1min)
Mechanical endurance, not less
cycles
10х106
Electrical endurance, not less
cycles
100000
Quantity and type of contacts
 
1 switching group
The degree's protection at case/terminals according to by GOST 14254-96
 
IP40/IP20/IP65
Operating temperature range (different versions)
0C
-25...+55 (UHL4)
-40…+55 (UHL2)
Storage temperature
0C
-40...+70
Immunity to interference from bursts in accordance with GOST R 51317.4.4-99 (IEC/EN 61000-4-4)   level 3 (2kV/5kHz)
Immunity to interference over voltage in accordance with GOST R 51317.4.5-99 (IEC/EN 61000-4-5)   level 3 (2kV A1-A2)
Climatic modification and placement category by GOST 15150-69 (non-condensing)
  UHL4 or UHL2
The degree of pollution in accordance with GOST 9920-89
  2
Relative humidity of air
%
up to 80 (at 250C)
Operating position in space
 
artbitrary
Mode
 
round the clock
Dimensions
mm
18х93х62
Weight
kg
0,061
Type of remote the photo senson (supplied separately)
 
FD-3-1
Operating temperature of photo sensor
0C
-40...+60
Wire length to the external photo sensor
m
up to 30
Cross section of connection wire
mm2
0,75
 
DIAGRAM OF OPERATING THE RELAY
Диаграмма работы ФР-М02
 
CIRCUIT CONNECTION
Схема подключения ФР-М02 (1)   Схема подключения ФР-М02 (2)
 
DIMENSIONS OF THE RELAY
Габаритные размеры реле контроля фаз ЕЛ-11М-15
 
Title
Order code
File to download
(manual)
File date
FR-M02 АС230V UHL4 with sensor
4640016935888
v08.11.2015
FR-M02 АС230V UHL4 without sensor
4640016935871
FR-M02 АС230V UHL2 with sensor
4640016935864
FR-M02 АС230V UHL2 without sensor
4640016935857
FR-M02 DС24V YHL2 with sensor
4640016935840
FR-M02 DС24V UHL2 without sensor
4640016935833

 

English
You are reporting a typo in the following text:
Simply click the "Send typo report" button to complete the report. You can also include a comment.