Phase control relay RKF-M06-11-15 common industrial execution

Реле контроля фаз РКФ-М06-11-15
RKF-M06-11-15 AС415V UHL4
1932.00 руб. с НДС

RKF-M06-11-15 AС415V UHL2
1932.00 руб. с НДС

RKF-M06-11-15 AС400V UHL4
по запросу

RKF-M06-11-15 AС400V UHL2
1932.00 руб. с НДС

RKF-M06-11-15 AC230V UHL4
1932.00 руб. с НДС

RKF-M06-11-15 AC110V UHL4
1932.00 руб. с НДС

RKF-M06-11-15 AC100V UHL4
1932.00 руб. с НДС

RKF-M06-11-15 AC100V UHL2
1932.00 руб. с НДС

 
Distinctive features of the relay
A parameter/Title
RKF-M06-11-15
common industrial
RKF-M06-12-15
for electric motors
RKF-M06-13-15
for crane electric motors
Control of break phases
+
+
+
Control of "stiking" phases
+
+
+
Control of alternation of phases
+
+
no
Control of asymmetry phases
>30%
5...25% (adjustable)
Overvoltage control
1,3 Urated
1,3 Urated
1,3 Urated
Undervoltage control
0,8...1,1Urated (adjustable)
The common-mode lower of voltage below – 0,5Urated
Actuation delay, s
0,1-10
0,15
 
  • The fixed threshold on overvoltage 1,3 Urated
  • Adjustable lower threshold on off (0.8 ...1,1) Urated
  • Control of alternation of phases
  • Control of break phases
  • Control of "stiking" phases
  • Adjustable actuation delay 0,1...10s
  • Power of relay is carried out from the controlled net
 
PURPOSE OF THE RELAY
 Phase control relay RKF-M06-11-15 is designed to control three-phase line voltage in three-wire net (without neutral). Relay controls an order of alternation of phases, break and "sticking" phases, voltage asymmetry, overvoltage above a fixed value, undervoltage below the set threshold. Technical characteristics of the relay shown in the table.
 
DESIGN OF THE RELAY
 Relay is produced in a plastic case with a unified front connection wires power and switched circuits. Mounting is carried out on a DIN rail  width 35mm (GOST R IEC 60715-2003) or on a smooth surface. To set on a smooth surface, spring locks must be changed in recent holes, fixing a spring lock, which are located on the back side of the case. Terminal design provides robust clamp wires up to 2,5mm2. On the front panel there are: rotary switch the operating time, rotary switch of operation threshold "Uphase%", the green indicator "U" of availability the supply voltage, yellow indicator "R" of the built-in executive relay.
 
OPERATION OF THE RELAY
 Voltage of phases A, B and C of controlled net is connected to appropriate terminals L1, L2, L3 of relay. The output relay contacts are connected to the control circuit. If the relay is connected correct, green and yellow LEDs are burning. If only green indicator burns, you have to check the voltage at the terminals and the correct of order of the alternation connected phases.
 When power is applied to the relay, lights up green LED «U» and is carried out a checking of all controlled parameters. If all parameters are normal, turns on a built-in executive relay (contacts of relay 11-12 and 21-22 - openes, contacts of relay 11-14 and 21-24 - closes) and yellow LED «R» lights up .
 Upon detection of a reverse alternation of phases, disappearance of two or three phases or in excess of a fixed threshold voltage equal 1,3Urated -  a relay switches off without counting of the set delay the operating time. At deviation Urated  from value of set threshold, at phase asymmetry, at "stiking" phases or at break of one phase the relay is turns offafter time t, that user set. After returning parameters to normal the relay turns on without delay. Operation relay shown at figure below, where "t" - set time delay.
 
SPECIFICATION OF THE RELAY RKF-M06-11-15
A parameter
Unit
АС100V
AC110V AC230V AC400V AC415V
Rated voltage Urated 50Hz
V
100
110 230 400 415
Minimum allowable line voltage
V
50
55 120 200 208
Maximum allowable line voltage
V
150
165 340 540 560
Ranges of adjustment the lower operation threshold
V
(0,8...1,1) Urated
Power consumption, max
VA
2
Deviation of counting operation threshold
V
0,05Urated
Deviation of setting operation threshold
%
±5Urated
Hysteresis of voltage operation threshold
V
0,02 Urated
Time off the built-in relay:
 undervoltage below 0,8...1,1 Urated
s
0,1-10
break of one phase
s
0,1-10
break of two or three phases
s
0,1
reverse order of alternation phases
s
0,1
"stiking" phases
s
0,1-10
overvoltage above 1,3Urated ±5%
s
0,1
Deviation of operating time, not more
%
±10
Maximum switching current: AC250V 50Hz (AC1)/DC30V (DC1)
A
8
Maximum switching power: АС250V 50Hz (АС1)/DC30V (DC1)
VA/W
2000/240
Maximum switching voltage
V
400 (AC1/2A)
The maximum voltage between the power supply circuits and relay contacts
V
AC2000 (50Hz - 1min)
Mechanical endurance, not less
cycles
10х106
Electrical endurance, not less
cycles
100000
The degree's protection at case/terminals according to by GOST 14254-96
 
IP40/IP20
Quantity and type of contacts
 
2 switching groups
Operating temperature range (different versions)
0C
-25...+55 (UHL4)
-40...+55 (UHL2)
Storage temperature
0C
-40...+70
Immunity to interference from bursts in accordance with GOST R 51317.4.4-99 (IEC/EN 61000-4-4)
 
level 3 (2kV/5kHz)
Immunity to interference over voltage in accordance with GOST R 51317.4.5-99 (IEC/EN 61000-4-5)
 
level 3 (2kV L1-L2)
Climatic modification and placement category by GOST 15150-69 (non-condensing)
 
UHL4 or UHL2
The degree's protection at case/terminals according to by GOST 14254-96
 
IP40/IP20
The degree of pollution in accordance with GOST 9920-89
 
2
Relative humidity of air
%
up to 80 (at 250C)
Height above sea level
m
till 2000
Operating position in space
 
artbitrary
Mode
 
round the clock
Dimensions
мм
18х93х62
Weight
kg
0,07
 
DIAGRAMS OF OPERATING THE RELAY
Диаграмма работы РКФ-М06-11-15
 
CIRCUIT CONNECTION
Схема подключения РКФ-М06-11-15
 
DIMENSIONS OF THE RELAY
Габаритные размеры реле контроля фаз ЕЛ-11М-15
 
Title
Order code
File to download
(manual)
File date
RKF-M06-11-15 AС415V UHL4
4640016934812
v07.10.2015
RKF-M06-11-15 AС415V UHL2
4640016934805
RKF-M06-11-15 AС400V UHL4
4640016934799
RKF-M06-11-15 AС400V UHL2
4640016934782
RKF-M06-11-15 AC230V UHL4
4640016934775
RKF-M06-11-15 AC110V UHL4
4640016934768
RKF-M06-11-15 AC100V UHL4
4640016934751
RKF-M06-11-15 AC100V UHL2
4640016931743
 
English
You are reporting a typo in the following text:
Simply click the "Send typo report" button to complete the report. You can also include a comment.