Time relay RVO-15 with delay on or off, a smooth installation, 2 switching contacts, possibly execution UHL2, TM (climatic performance)

Реле времени однокомандное РВО-15

RVO-15 АСDC24V/АС230V UHL4
1450.00 руб. с НДС

RVO-15 ACDC24V/АС230V UHL2
1740.00 руб. с НДС

RVO-15 ACDC24V/АС230V TM
1740.00 руб. с НДС

RVO-15 ACDC10-30V UHL4
1450.00 руб. с НДС

RVO-15 ACDC10-30V UHL2
1740.00 руб. с НДС

 
  • Time delay range from 0,1s to 99h
  • Setting time delay by using the turning decade switches
  • Two operating diagrams
  • 2 switching groups 8A/250V
  • The status indicator built-in relay, indicator of availability of power
  • Width of the case is 18mm
 
PURPOSE OF THE RELAY
 Time relay RVO-15 is designed to issuing commands in the chain of control circuits through the relay contacts after working off set time delay for a given algorithm operation.
 
DESIGN OF THE RELAY
 Relay is produced in a plastic case with a unified front connection wires power and switched circuits. Mounting is carried out on a DIN rail  width 35mm (GOST R IEC 60715-2003) or on a smooth surface. To set on a smooth surface, you need to push locks. Terminal design provides robust clamp wires up to 2,5mm2. On the front panel there are: two turning switches to set the delay time t (setting value units 0-9 and 0-9 tens), the unit switches "multiplier" to choose the diagram and set the time range, the green LED turn on «U» power supply, yellow built-in executive relays activation indicator "".
 
OPERATION OF THE RELAY
 Diagram of operation and timing range diagram are selected using the switch block "1-4". For each diagram can be choose one of the eight exposure time ranges by setting switches 1-3 to the appropriate position. Diagram of operation is defined by the switch in position "4". The required time delay t is set by the rotary switches, the first significant digit - a switch "tens.", the second significant digit - a switch "unit".
 When choosing the first diagram with "pause" (pause duration determines the delay in the inclusion of built-in electromagnetic relay from the beginning of the power supply to the unit at time t) in the interval the set delay time t contacts 15-16 and 25-26 are closed . After the counting time delay t, built-in electromagnetic relay is on, contacts 15-18 and 25-28 closes and the yellow LED lights up "".
 When choosing the second diagram with "pulse" (built-in electromagnetic relay is activated simultaneously with the turning on the power at time t) with the supply of voltage built-in electromagnetic relay is activated, the yellow LED lights up "", contacts 15-18 and 25-28 closes and counting begins delay time t. After the counting delay time t, built-in an electromagnetic relay is switched off, contacts 15-16 and 25-26 closes and the yellow LED goes out "".
 
 WARNING:  To change the range of delay time a relay must be off.
 
SPECIFICATION OF THE RELAY  RVO-15
A parameter Unit RVO-15 ACDC24V/AC230V RVO-15 ACDC10-30V
Supply voltage
V/Hz
АС230 ± 10%
АСDC10-30
Range of the delays time
 
0,1-9,9s, 1-99s, 10-990s, 0,1-9,9min, 1-99min, 10-990min, 0,1-9,9h, 1-99h
Deviation of installation time delay, not more % 10
Deviation of counting time delay, not more
%
2
Availability time, not more
s
0,15
Repeated availability time, not more
s
0,1
Operating diagrams   1, 2
Maximum switching current: AC250V 50Hz (AC1)/DC30V (DC1) A 8
Maximum switching voltage
V
400 (AC1/2A)
Maximum switching power: АС250V 50Hz (АС1)/DC30V (DC1) VA/W 2000/240
The maximum voltage between the power supply circuits and relay contacts
V AC2000 (50Hz - 1min)
Power consumption, max
VA
2
Mechanical endurance, not less
cycles
10х106
Electrical endurance, not less
cycles
100000
Quantity and type of contacts
 
2 switching groups
Operating temperature range (different versions)
0C
-25…+55 (UHL4)
 -40…+55 (UHL2)
 -1…+55 (TM)
Storage temperature
0C
-40...+70
Immunity to interference from bursts in accordance with GOST R 51317.4.4-99 (IEC/EN 61000-4-4)   level 3 (2kV/5kHz)
Immunity to interference over voltage in accordance with GOST R 51317.4.5-99 (IEC/EN 61000-4-5)   level 3 (2kV A1-A2)
Climatic modification and placement category by GOST 15150-69 (non-condensing)
  UHL4 or UHL2 or TM
The degree's protection at case/terminals according to by GOST 14254-96
  IP40/IP20
The degree of pollution in accordance with GOST 9920-89
  2
Relative humidity of air
%
80 (at 250C)
Height above sea level
m
2000
Operating position in space
 
artbitrary
Mode
 
round the clock
Dimensions
mm
18х93х62
Weight
kg
0,07
 
DIAGRAMS OF OPERATING THE RELAY
Диаграмма работы реле времени № 1
 The counting the set time begins when power is applied, after which the relay switches (switch-on delay). It is turned off, when the power is off.
Диаграмма работы реле времени № 2
 The relay is turned on simultaneously with power supply. Disabling the relay occurs after the set time counting (tripping delay).
 
CIRCUIT CONNECTION
Схема подключения РВО-15
Схема подключения РВО-15 (1)
 Voltage supply DC6V is fed to the terminals «+A1», «A2», «+» is connected to the terminal «+А1».
 Voltage supply АСDC24V is fed to the terminals «+A3», «A2», «+» is connected to the terminal «+A3». Voltage supply AC230V is fed to the terminals «A1», «A2».
 
DIMENSIONS OF THE RELAY
Габаритные размеры реле в корпусе 18*93*62мм
 
Title
Order code
File to download
(manual)
File date
RVO-15 АСDC24V/АС230V UHL4
4640016932887
v10.09.2015
RVO-15 ACDC24V/АС230V UHL2
4640016932870
RVO-15 ACDC24V/АС230V TM
4640016932863
RVO-15 ACDC10-30V UHL4
4640016930616
RVO-15 ACDC10-30V UHL2
4640016930609
English
You are reporting a typo in the following text:
Simply click the "Send typo report" button to complete the report. You can also include a comment.