  • Straight, inverse count of pulses or mode or digital scale (reverse)
  • Mode of summation for two inputs
  • The actual measurement units
  • Showing the value to thousandths of
  • Calculation of equipment operating time (counting hours)
  • Load control by two built-in relays
  • Saving results of count when power is off
 
PURPOSE OF COUNTER OF PULSES
 Counter of pulses SIM-05-1 is used to count the number of products, length of dimensional material, sorting products, reference batches of products, the total number of products, etc. It provides straight, inverse or reverse count of pulses. Built-in timer allows you to use the device as a counter of operating time of equipment.
 
DESIGN OF COUNTER OF PULSES
 The couter is mounted on a smooth surface (SIM-05-1-17) or on a shield (SIM-05-1-09). A material of case - impact polystyrene. The front panel has four control buttons and a six-digit indicator. In the counter SIM-05-1-17 from below of case are located hermetic inputs for the output of wires that are connected to the equipment. For installation the device it is necessary to secure it with screws and bolts in the hole of the case. At the counter SIM-05-1-09 behind is located terminal blocks for wires, that connected to equipment. For installation the device it is necessary to cut out in the panel a window with dimensions 94*94mm, to place the device in the window, to install on the side surface of the device mounting brackets, that included in the delivery, and to attach by screws the device to the panel. As an extenal device can be used any (optical, inductive, capacitive contact) sensors, that having an output transistor NPN or PNP open collector keys, HTL-output and dry contact.
 
OPERATION OF COUNTER
 Operation is carried out in the operation mode or setting mode. When powering the counter is in operation and analyzes input signals, and count of pulses and control of built-in relays take place on the algorithm of count, set by the factory settings (see factory settings). All other parameters of the counter are determined by the user in the settings menu. Accessing the settings menu can be accessed after entering the PIN-code.
 
 WARNING: PIN-code is printed on the rear wall of counter's case.
 WARNING: The counter is designed for non-commerce accouting. Is possible to use for process control.
 
SPECIFICATION OF COUNTER OF PULSES SIM-05-1
A parameter Unit SIM-05-1-17, SIM-05-1-09
Supply voltage V/Hz АС160...240/ 50 DC24 DC12
Internal adapter of sensor power V DC12 DC24 DC12
Maximum consumption of sensors mA 90
The number of digits of display
unit
6
The range of limits of counting events
unit
-99999…999999
Accounting for cumulative operating
h
999999 units of most significant digit
999.999 units of least significant digit
Accounting for cumulative operating time
h
999999
The main deviation of counting time, not more
%
5
The range of tasks a conversion factor
unit
0,00001...9,99999
The range of tasks prescaler of counter inputs
unit
1...9999
The range of speed setting of count software filter
s
0...9,9999
The range of setting of operating time of output relays
s
0...9,9
The number of inputs (Count1, Count2, Reset, Locking)
unit
4
Type of connected sensors (hardware coordination)
 
NPN, PNP, HTL, or "dry" contact
The level of logical zero "logic 0"
V
0...2
The level of the logical unit  "logic 1"
V
8...15
The maximum frequency of the input pulses Count1 and Count2 (is achieved when the duty ratio is 2)
кГц
20
The minimum duration of the input pulse Count1 and Count2
mcs
25
The maximum frequency of input pulses Count1 and Count2 at operation diagram 03
kHz
10
The minimum duration of input signal (Reset and Locking)
ms
40
The number of output relays
 
2*1 switching group
Maximum switching voltage
V
400
Maximum switching current: AC250V 50Hz (AC1)/DC30V (DC1)
A
5
Maximum switching power: АС250V 50Hz (АС1)/DC30V (DC1) VA/W 1250/150
Dimensions
mm
82*80*56 (SIM-05-1-17)
96*96*75 (SIM-05-1-09)
Size of indication window
mm
14*47(SIM-05-1-17)
20*76 (SIM-05-1-09)
Height of digit
mm
10 (SIM-05-1-17)
15 (SIM-05-1-09)
The degree's protection
 
IP54 (SIM-05-1-17)
IP54 (at face panel)/IP20 (at terminals) (SIM-05-1-09)
Operating temperature range (different versions)
0C
-25…+55 (UHL4)
-40...+55 (UHL2)
+1...+55 (TM)
Storage temperature
0C
-40...+70
Immunity to interference from bursts in accordance with GOST R 51317.4.4-99 (IEC/EN 61000-4-4)
  level 3 (2kV/5kHz)
Immunity to interference over voltage in accordance with GOST R 51317.4.5-99 (IEC/EN 61000-4-5)
  level 3 (2kV A1-A2)
Climatic modification and placement category by GOST 15150-69 (non-condensing)
  UHL4 or UHL2 or TM
The degree of pollution in accordance with GOST 9920-89
  2
Relative humidity of air % up to 80 (at 250C)
Height above sea level m till 2000
Operating position in space
  artbitrary
Mode
 
round the clock
Period of storage information when power is off
 
not limited
Weight, not more kg 0,5

 

DIAGRAMS OF OPERATING OF COUNTER OF PULSES

Диаграмма работы СИМ-05-5 (1)
 Operation mode 01. The relay 1 turns on when it reaches the value (Threshold 1) for a predetermined hold time. Upon reaching the value (Threshold 2) the current value of counter is reset to zero and turns on the relay 2 to a predetermined hold time.
Диаграмма работы СИМ-05-1 (2)
 Operation mode 02. Relay 1 turns on when the value of an account is equal to the value (Threshold 2) minus the value (pre-emption). Turning off the relay 1 occurs when the value (Threshold 2), at the same time the current value of counter is reset to zero and turns on the relay 2 for a predetermined holding time.
 WARNING: The maximum value of "pre-emption" is equal to the value "Threshold 2" minus one account.
Диаграмма работы СИМ-05-1 (3)
 Operation mode 03. The relay 1 turns on when it reaches the value (Threshold 1) and turns off when it reaches the value of count that equal (Threshold 1) minus one. The relay  2 turns on when it reaches the value (Threshold 2) and turn off at value of count that equal  (Threshold 2) minus one.

DIAGRAMS OF COUNTING SIM-05-1
Диаграмма счётв СИМ-05-1 (1)
 Diagram of count 01
 A counter sums pulses that reach the input Count1 and to the input Count2. At the command Reset a value of counter is reset to zero. In settings set parameters of pulse, at wich is produced an actuation of reading device (front or rear edge).
Диаграмма счёта СИМ-05-1 (2)
 Diagram of count 02
 Account of pulses occurs at the input Count1
 The pulse at the input Count2 sets the direction of account.
 The value of level of logical "0" in the point of settings menu sets the account at the sum. The value of the level of logical "1" sets the the account to subtraction. At the command Reset the value of counter is reset to zero. Setting input parameters is provided in the settings menu.
Диаграмма счёта СИМ-05-1 (3)
 Diagram of count 03 - a mode digital scale (reverse)
 Reversing account enables to sum and subtract pulses, that are received on inputs Count1 and Count2. An obligatory condition for the summation is to complete a full cycle of changes in the input signals:
1. Count1 the change input voltage from "logic0" to "logic1"
2. Count2 the change input voltage from "logic0" to "logic1"
3. Count1 the change input voltage from "logic1" to "logic0"
4. Count2 the change input voltage from "logic1" to "logic0"
 An obligatory condition for subtraction is the completion of a full cycle of changes in the input signals:
1. Count2 a drop input voltage from "logic0" to "logic1"
2. Count1 a drop input voltage from "logic0" to "logic1"
3. Count2 a drop input voltage from "logic1" to "logic0"
4. Count1 a drop input voltage from "logic1" to "logic0"
 At the command Reset a value of counter is rest to zero.
 It is used when dealing with incremental encoders.
Диаграмма счёта СИМ-05-1 (4)
 Diagram of count 04
 Account of pulses to input Count1 to the sum, to input Count2 to the subtraction. Reset the value of the counter is rest to zero.
 
CIRCUIT CONNECTION
Схема подключения СИМ-05-1-09    Схема подключения СИМ-05-1-17
 
DIMENSIONS OF SIM-05-1-17
Габариты 82*80*56
 
DIMENSIONS OF SIM-05-1-09
Габариты 96*96*63
 

Title
Order code
File to download
(manual)
File date
SIM-05-1-17 AC230V UHL4
4640016934614
05.06.2015
SIM-05-1-17 DC24V UHL4
4640016935406
SIM-05-1-17 DC12V UHL4
4640016935383
SIM-05-1-09 АС230V UHL4
4640016935369
SIM-05-1-09 DC24V UHL4
4640016935352
SIM-05-1-09 DC12V UHL4
4640016935345

 

English
You are reporting a typo in the following text:
Simply click the "Send typo report" button to complete the report. You can also include a comment.