Tachometer SIM-05t-1-17

Тахометр СИМ-05т-1-17
Тахометр СИМ-05т-1-09
17 case
09 case
SIM-05t-1-17 АС230V UHL4 2450.00 руб. с НДС

SIM-05t-1-17 DC10-30V UHL4 2450.00 руб. с НДС

SIM-05t-1-09 АС230V UHL4 2450.00 руб. с НДС

SIM-05t-1-09 DC10-30V UHL4 2450.00 руб. с НДС

 
  • Measuring the rate of arrival of input pulses (rotation of the motor shaft and so forth)
  • Counting of time operating of equipment and number of inclusions (built-in function of hourmeter)
  • Saving results of account when power is off
 
 WARNING:  Counter is designed for process control equipment operating time. Counter is not intended for commercial account.
 
PURPOSE OF TACHOMETER
 Pulse counter (tachometer) SIM-05t-1-17 is designed to measure and display on the digital display motor shaft speed in rev/min, as well as for counting the total motor rotation time (operating time) and the number of inclusions (number of starts). When the engine speed reaches zero, counting operating time is suspended. The results are saved in non-volatile memory during a power failure. The information storage time is not limited.
 
DESIGN OF TACHOMETER
 The couter is mounted on a smooth surface.  A material of case - impact polystyrene. The front panel has a six-digit indicator of red illuminationand a button to switch indication modes. In the counter below of case are located hermetic inputs for the output of wires that are connected to the equipment. For installation the device it is necessary to secure it with screws and bolts in the hole of the case, that are located at the corners of the case. 
 As an extenal device can be used optical, inductive, capacitive or contact sensors, that having an output transistor NPN or PNP open collector keys.
 
Connecting sensors of various types
Схема подключения датчика типа NPN к СИМ-05т-1-17(09)
Схема подключения датчика типа PNP к СИМ-05т-1-17(09)
Схема подключения датчика контактного типа к СИМ-05т-1-17(09)
 
OPERATION OF TACHOMETER
 At power the counter indicates speed of shaft rotation. According to frequency of pulse follow from a sensor, wich controls a label on the shaft of motor, is calculated the shaft rotation speed (revolutions per minure) and display the current value on the indicator. Button "" on the front panel allows you to see the engine operating time and number of starts. Number of involved indicator digits, that set aside for indication of hours, minutes and seconds, is determined by the number of operated hours. On the indicator digits set aside for hours/minutes/seconds, are separated by dots. As the number of digits, occupied by the counted clock, location of dividing point moves to the right and, accordingly, is reduced the number of least significant bits, originally set aside for indication units of seconds, tens of seconds, units of minutes and tens of minutes. 
 Resetting the total operating time and number of inclusions is produced by contact closure JP2 on the power board in the following order:
     - Remove the power from the counter.
     - Remove jumper from contacts JP2.
     - Apply power to the counter.
     - Remove power from the counter set the jumper to the contacts JP2.
 Beginning of count down starts when you turn on the power.
 
 WARNING: Connecting of counter and setting the jumper must be carried out only after power is removed
 
SPECIFICATION OF TACHOMETER
A parameter
Unit
SIM-05t-1-17 AC230V
SIM-05t-1-17 DC10-30V
Supply voltage
V
AC230 (50Hz)
DC10...30
Internal adapter of sensor power
V
DC12
Maximum consumption of sensors
mA
90
The number of digits of display
 
6
The maximum frequency of the input  pulses (at duty ratio 2)
kHz
20
The minimum duration of the input signal
mcs
25
The main deviation of measurement of speed, not more
%
±0,1
Maximum time of pulse repetition, not more
s
2
Maximum total operating time of engine
h
till 999999
Accounting for the number of starts
 
till 999999
The main deviation of counting time, not more
%
± 0,1
The number of inputs (Count1)
 
1
Type of connected sensors (hardware coordination)
 
NPN, PNP, contact sensor
The level of logical zero "logic 0"
V
0...2
The level of logical unit "logic 1"
V
8...15
Operating temperature range 0C -25...+55
Storage temperature 0C -40...+70
Immunity to interference from bursts in accordance with GOST R 51317.4.4-99 (IEC/EN 61000-4-4)
  level 3 (2kV/5kHz)
Immunity to interference over voltage in accordance with GOST R 51317.4.5-99 (IEC/EN 61000-4-5)
  level 3 (2kV A1-A2)
Dimensions
mm
82х80х56
Size of indication window
mm
14х47
Height of digit
mm
10
The degree's protection at GOST 14254-96
 
IP54
Climatic modification and placement category by GOST 15150-69 (non-condensing)
 
UHL4
The degree of pollution in accordance with GOST 9920-89
  2
Relative humidity of air % up to 80 (at 250C)
Height above sea level   till 2000
Weight, not more
kg
0,21
Operating position in space
  artbitrary
Mode
 
round the clock
Period of storage information when power is off
 
not limited
 
CIRCUIT CONNECTION
Схема подключения СИМ-05т-1-17(09)
 
DIMENSIONS
Габариты 82*80*56
 
Title
Order code
File to download
(manual)
File date
SIM-05t-1-17 АС230V UHL4
4640016935505
04.06.2015
SIM-05t-1-17 DC10-30V UHL4
4640016935512

 

English